=== Experimental Data and Discussion ===
=== Experimental Data and Discussion ===


50uL of purified protein from the first elution was added to 3mL of cold 1mg/mL PNPA at pH=7.30. Chloride ion cofactor was provided by the 2M HCl. A change in absorbance at 428.7nm over time was noted. The time range of the run did not produce a linear response. The absorbance increased for the first ten minutes and plateaued.  The time 0 to 10 minutes was used to create the third figure with a more refined linear range.   
50uL of purified protein from the first elution was added to 3mL of cold 1mg/mL PNPA at pH=7.30. Chloride ion cofactor was provided by the 2M HCl. A change in absorbance at 428.7nm over time was noted. The time range of the run did not produce a linear response. The absorbance increased for the first ten minutes and plateaued.  The time 0 to 10 minutes was used to create the third figure with a more refined linear range.  
 
   
[[Image:Absorbancecoldph7try.png|400px|left|A trendline showing the potential relationship between absorbance and time from the data gathered from the PNPA+Protein solution with pH = 7, sodium chloride, and a cold environment.]]
[[Image:Absorbancecoldph7try.png|500px|left|]]


A linear equation of y=9.275x10^-7x+1x10^-4 with a coefficient of determination of 0.8492 was calculated using linear regression.