1jbz

From Proteopedia

Jump to: navigation, search

CRYSTAL STRUCTURE ANALYSIS OF A DUAL-WAVELENGTH EMISSION GREEN FLUORESCENT PROTEIN VARIANT AT HIGH PH

Structural highlights

1jbz is a 1 chain structure with sequence from Aequorea victoria. Full crystallographic information is available from OCA. For a guided tour on the structure components use FirstGlance.
Method:X-ray diffraction, Resolution 1.5Å
Ligands:CRO, EDO, MG
Resources:FirstGlance, OCA, PDBe, RCSB, PDBsum, ProSAT

Function

GFP_AEQVI Energy-transfer acceptor. Its role is to transduce the blue chemiluminescence of the protein aequorin into green fluorescent light by energy transfer. Fluoresces in vivo upon receiving energy from the Ca(2+)-activated photoprotein aequorin.

Evolutionary Conservation

Check, as determined by ConSurfDB. You may read the explanation of the method and the full data available from ConSurf.

Publication Abstract from PubMed

Novel dual emission, pH-sensitive variants of the green fluorescent protein (GFP) have been constructed and are suitable for ratiometric emission measurements in vivo. This new class of GFPs, termed deGPFs, results from substitution of wild-type residue 65 with threonine and residues 148 and/or 203 with cysteine. deGFPs display pK(a) values ranging from 6.8 to 8.0 and emission that switches from a green form (lambda(max) approximately 515 nm) to a blue form (lambda(max) approximately 460 nm) with acidifying pH. In this report we analyze in most detail the deGFP1 variant (S65T/H148G/T203C, pK(a) approximately 8.0) and the deGFP4 variant (S65T/C48S/H148C/T203C, pK(a) approximately 7.3). In the following paper [McAnaney, T. B., Park, E. S., Hanson, G. T., Remington, S. J., and Boxer, S. G. (2002) Biochemistry 41, 15489-15494], data obtained by ultrafast fluorescence upconversion spectroscopy can be described by a kinetic model that includes an excited-state proton-transfer pathway at high pH but not at low pH. Crystal structure analyses of deGFP1 at high-pH and low-pH conformations were performed to elucidate the basis for the dual emission characteristics. At low pH the structure does not contain a hydrogen bond network that would support rapid transfer of a proton from the excited state of the neutral chromophore to a suitable acceptor; hence blue emission is observed. At high pH, backbone rearrangements induced by changes in the associated hydrogen bond network permit excited-state proton transfer from the excited state of the neutral chromophore to the bulk solvent via Ser147 and bound water molecules, resulting in green emission from the anionic chromophore. Comparative analysis suggests that the basis for dual emission is elimination of the wild-type proton-transfer network by the S65T substitution, a general reduction in hydrogen-bonding opportunities, and a concomitant increase in the hydrophobic nature of the chromophore environment resulting from the cysteine substitutions. We evaluated the suitability of the deGFP4 variant for intracellular pH measurements in mammalian cells by transient expression in PS120 fibroblasts. The responses of deGFP4 and a commercially available pH-sensitive dye, SNARF-1, to changes in pH were compared in the same cells. Results show that the dynamic range of the emission ratio change is comparable between the two pH sensors over the range examined. Two-photon excitation was found to elicit a better deGFP4 fluorescent signal above cellular autofluorescence when compared to conventional confocal microscopy. Given their favorable optical characteristics, suitable pK(a)'s for the physiological pH range, and suitability for ratiometric measurements, dual emission GFPs should make excellent probes for studying pH in vivo.

Green fluorescent protein variants as ratiometric dual emission pH sensors. 1. Structural characterization and preliminary application.,Hanson GT, McAnaney TB, Park ES, Rendell ME, Yarbrough DK, Chu S, Xi L, Boxer SG, Montrose MH, Remington SJ Biochemistry. 2002 Dec 31;41(52):15477-88. PMID:12501176[1]

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine.

Loading citation details..
Citations
No citations found

See Also

References

  1. Hanson GT, McAnaney TB, Park ES, Rendell ME, Yarbrough DK, Chu S, Xi L, Boxer SG, Montrose MH, Remington SJ. Green fluorescent protein variants as ratiometric dual emission pH sensors. 1. Structural characterization and preliminary application. Biochemistry. 2002 Dec 31;41(52):15477-88. PMID:12501176

Contents


PDB ID 1jbz

Drag the structure with the mouse to rotate

Proteopedia Page Contributors and Editors (what is this?)

OCA

Personal tools