Structural highlights
Publication Abstract from PubMed
High-resolution structural information is essential to understand protein function. Protein-structure determination needs a considerable amount of protein, which can be challenging to produce, often involving harsh and lengthy procedures. In contrast, the several thousand to a few million protein particles required for structure determination by cryogenic electron microscopy (cryo-EM) can be provided by miniaturized systems. Here, we present a microfluidic method for the rapid isolation of a target protein and its direct preparation for cryo-EM. Less than 1 muL of cell lysate is required as starting material to solve the atomic structure of the untagged, endogenous human 20S proteasome. Our work paves the way for high-throughput structure determination of proteins from minimal amounts of cell lysate and opens more opportunities for the isolation of sensitive, endogenous protein complexes.
Microfluidic protein isolation and sample preparation for high-resolution cryo-EM.,Schmidli C, Albiez S, Rima L, Righetto R, Mohammed I, Oliva P, Kovacik L, Stahlberg H, Braun T Proc Natl Acad Sci U S A. 2019 Jul 10. pii: 1907214116. doi:, 10.1073/pnas.1907214116. PMID:31292253[1]
From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine.
References
- ↑ Schmidli C, Albiez S, Rima L, Righetto R, Mohammed I, Oliva P, Kovacik L, Stahlberg H, Braun T. Microfluidic protein isolation and sample preparation for high-resolution cryo-EM. Proc Natl Acad Sci U S A. 2019 Jul 10. pii: 1907214116. doi:, 10.1073/pnas.1907214116. PMID:31292253 doi:http://dx.doi.org/10.1073/pnas.1907214116